VA3 PRO
3-Channel Vibration Analyzer, Data Collector and Many More
A true vibration analyzer
real time FFTs, time waveforms etc.
Modularly based
buy only the modes you need
User friendly interface
graphical balancing mode
![](https://bafco-reliability.com/wp-content/uploads/2020/10/1-1.png)
WHAT’S IN THE BOX?
![](https://bafco-reliability.com/wp-content/uploads/2020/10/2.png)
Customize your VA3 Pro kit.
Select a single axis acceleration sensor or triaxial sensor for your day to day data collection.
A speed probe would be needed for balancing job and an ultrasound probe for leak detection.
No problem measuring Orbits, Centerline using Proximity probes.
VERSATILITY & CONNECTIVITY
![](https://bafco-reliability.com/wp-content/uploads/2020/10/3.jpg)
3x AC input – vibrations
3x DC input – process values
1x Trigger input (speed probe)
Triaxial sensor ready
IR temperature sensor
LED stroboscope / flashlight
Fast USB 2.0 communication
Robust Push-Pull connectors
VA3 PRO MODULES
TECHNICAL SPECIFICATIONS
Input channels:
3 x AC, ICP® power supply on/off
3 x DC for process values
1 x TACHO for speed probe / external trigger
3 x DC for process values
1 x TACHO for speed probe / external trigger
Input range:
AC +/- 12 V peak-peak
DC +/- 24V
DC +/- 24V
AD conversion:
24 bit, 64 bit internal signal processing
No AutoGain function!
No AutoGain function!
Dynamic range S/N:
120 dB
Frequency ranges (-3 dB):
Maximum range: 0.5 Hz – 25 kHz (64 kHz sampling)
Minimum range: 0.5 Hz – 25 Hz (64 Hz sampling)
Minimum range: 0.5 Hz – 25 Hz (64 Hz sampling)
Sampling mode:
Fully simultaneous for all 3 channels
FFT resolution:
Min. 25 lines
Max. 25 600 lines
Max. 25 600 lines
Measurement modes:
Analyzer – analytical measurements
Data collector – route measurements
Balancer – 1 and 2 plane on site balancing
Recorder – raw signal recording for later post analysis
Run Up – run up and coast down measurements
Ultrasound – measurement of ultrasound in 30 – 50 kHz range
LED stroboscope, LED torch
FASIT – Expert system for automatic fault detection
Vibration meter – basic vibration measurements
Data collector – route measurements
Balancer – 1 and 2 plane on site balancing
Recorder – raw signal recording for later post analysis
Run Up – run up and coast down measurements
Ultrasound – measurement of ultrasound in 30 – 50 kHz range
LED stroboscope, LED torch
FASIT – Expert system for automatic fault detection
Vibration meter – basic vibration measurements
Software:
Free version of DDS software (limited database size)
Licensed DDS software
Licensed DDS software
Data processing:
Real time FFT
DEMOD – ENVELOPE analysis
ACMT – low speed bearing analysis
Order analysis
User band pass analysis
RPM measurement
DC measurement
Orbit measurement
DEMOD – ENVELOPE analysis
ACMT – low speed bearing analysis
Order analysis
User band pass analysis
RPM measurement
DC measurement
Orbit measurement
IR temperature measurement:
From -70˚C to +380˚C (-94˚F to +716˚F)
Trigger:
Manual, External, Amplitude, Tacho
Display:
Colour 240 x 320 pixels, TFT
Interface:
USB 2.0, 3.0 compatible
Operating temperature range:
-10˚C to +50˚C
Power:
Battery pack for more than 10 hours of continous operation
Case:
Aluminium – heavy duty (optionally with IP65 rating)
Weight:
780 g
Dimensions:
230 x 82 x 32 mm
Languages:
Languages: English, Spanish, German, French, Portuguese, Russian, Czech, Hungarian, Polish